A RAID5 SVM configuration is setup across three disks - c0t1d0, c0t2d0 and c0t3d0. Note: The DevID information at the bottom. and will keep posting here the questions. 0 Kudos Reply thanks for clarifying. These changes affect both the client and server machines. http://bashprofile.net/failed-to/cfgadm-library-error-report-luns-failed.html

View solution in original post 0 Kudos Reply 9 Replies as cfgadm -c configure is g_lee Level 6 ‎11-20-2009 10:23 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed If there are any replicas on this disk, remove them using:metadb -d c#t#d#s#Verify there are no existing replicas left on the disk, by running:metadb grep c#t#d#3. DuckieM10 I'm trying to install a new operating system on to my computer but, they won't install because its having a hard time copying files to the hard disk. Close Login Didn't find the article you were looking for? https://docs.oracle.com/cd/E24355_01/html/E41214/z40023252072622.html

Cfgadm Force Unconfigure

Blog O' Matty Home Blog Home Articles Code Presentations Replacing failed disk devices with the Solaris Volume Manager While reviewing a post I left on blogs.sun.com, I noticed that Jerry Jelinek If Step a fails with the following error, the drive might still be active.# cfgadm -c unconfigure Ap_Id cfgadm: Hardware specific failure: failed to unconfigure SCSI device: I/O errorIf the error appears, rather than deleting config details from the dg, remove disk for replacement: - run: vxdiskadm -> option 4 (Remove a disk for replacement) [follow prompts] - then the OS steps (cfgadm Don't have a SymAccount?

  1. Try these resources.
  2. cfgadm -c configure c#::dsk/c#t#d# cfgadm -al (just to confirm that disk is configured properly)6.
  3. CPUs on a Board Must Be Configured Before Memory Before configuring memory, all CPUs on the system board must be configured.
  4. I/O Board Unconfiguration Failure A device cannot be unconfigured or disconnected while it is in use.

dumpadm -d /dev/dsk/c1t1d0s1 Verify that the dump device is set to the new slice dumpadm And then go ahead and use the cfgadm -c unconfigure command to release the disk. Just out of above solution, was thinking, does Sun M5000 uses an internal FC disk ? thanks both for your help. 0 Kudos Reply sunguru, just to clarify, was g_lee Level 6 ‎11-24-2009 04:26 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Cfgadm: Configuration Operation Not Supported y Note – This step must be performed if you are removing a SCSI RAID device from a SCSI RAID array.

You can disable the device, or the entire controller. Cfgadm Unconfigure Disk If an unconfiguration operation fails because an I/O board has a busy or open device, the board is left only partially unconfigured. Note – If the SCSI device is not supported by the cfgadm command, the device does not display in the cfgadm command output. https://support.symantec.com/en_US/article.TECH159840.html c13                          scsi-sas    connected configured unknown c13::w5000cca02505cc11,0     disk-path   connected unconfigured unknown ...The output should display paths for both ports.

metareplace -e c#t#d#s#EXAMPLESThe following two examples illustrate the commands and sample outputs of the above procedures.Example 1: Replacing a Mirrored DiskIn this example, a Netra t1400 has only one SCSI Cfgadm: Insufficient Condition metadevadm -u c#t#d#7. The author will not be held liable for any problems that result from the information provided here.

Copyright Instances of netdata run independently on monitored systems.

Cfgadm Unconfigure Disk

The CPU is the last online CPU in the system. http://www.shrubbery.net/solaris9ab/SUNWdhshw/806-6783-10/trouble.html Bridged NICs. Cfgadm Force Unconfigure Enter y if operation is complete or n to abort (yes/no)? Cfgadm Command In Solaris The following example deletes all meta state databases on slice 7 of the disk (c0t0d0) that we are going to replace: $ metdb -d c0t0d0s7 Once the meta state databases are

Use the cfgadm -al command to display information about SCSI devices such as disk and tapes. By default, the dump device would read /dev/dsk/c0t0d0s1. Labels: Business Continuity Reporting Storage Foundation Tip-How to 1 Kudo Reply 1 Solution Accepted Solutions Accepted Solution! Solution Unmount the file system that is listed in the error message and retry the cfgadm operation. Cfgadm: Attachment Point Not Found

For example, if the parent VM had eth0, the clone will have eth1, and the clone of … Kodi Volume Control Stops Working All of a sudden, when using the remote Legal Notices Documentation Home > System Administration Guide: Devices and File Systems > Chapter 6 Dynamically Configuring Devices (Tasks) > SCSI Hot-Plugging With the cfgadm CommandSystem Administration Guide: Devices and File And it’s not just America that’s getting the attention. Example: # /usr/sbin/cfgadm -al | grep c0t0d0 c0::dsk/c0t0d0 disk connected configured unknown Then execute cfgadm -c unconfigure c0::dsk/c0t0d0.

Any one Please Advice Thanks, Senthilkumar.R senthilkumar on August 3rd, 2009 How to identify how many ram is currently utilize in per box in solaris. Luxadm Forcelip Remove the exclusion if you want to add this disk back into the VxVM configuration. Become superuser.

For example, if the DevID of c0t1d0 was: "SSEAGATE_ST318203_LR7943" and that disk is replaced with a new disk (whose DevID would be "SFUJITSU_MAG3182_005268"), Solaris will still report that the c0t1d0 disk

format [ the steps to create a valid partition table have been left out for brevity ]We run 'metadevadm' to update the SVM database with the new DevID information. Otherwise, future dynamic reconfiguration operations on this controller and target devices will fail with a dr in progress message. Note : The VTOC (volume table of contents) on the root disk and root mirror must be the same. Devfsadm root# cfgadm -c unconfigure c2::dsk/c2t11d0 cfgadm: Hardware specific failure: failed to unconfigure SCSI device: I/O error root# cfgadm -al|grep c2t11d0 c2::dsk/c2t11d0

cfgadm -c unconfigure c#::dsk/c#t#d# NOTE: if the message "Hardware specific failure: failed to unconfigure SCSI device: I/O error" appears, check to make sure that you cleared all replicas and metadevices from Sir June on July 12th, 2008 i have a failing disk c1t2d0 under Solaris 9: d15: Concat/Stripe Size: 573356544 blocks (273 GB) Stripe 0: (interlace: 32 blocks) Device Start Block Dbase Type y at the Enter y if operation is complete or n to abort (yes/no)? Submit a Threat Submit a suspected infected fileto Symantec.

Log In Username Password Remember Me Lost your password? My current hard drive has 189 GB but I'd like something with a lot more space, and preferably cheap… liza The usb ports work well enough with modem and camera. Many failures to unconfigure I/O boards occur because activity on the boards has not been stopped, or because an I/O device becomes active again after it has been stopped. Force Blader: Swordsman whose blade flares with th...

Run the 'cfgadm' command to remove the failed disk. Error Message cfgadm: Component system is busy, try again: failed to offline: device-path Resource Information ------------------ -------------------------- /dev/dsk/c1t0d0s0 mounted filesystem "/file-system" Cause You attempted to remove or replace a device with A CPU remains configured on the board. Lee, sorry for the typo , i sunguru Level 4 ‎11-24-2009 08:58 AM Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Highlight Print Email to a Friend Report Inappropriate

metadevadm -u c#t#d# NOTE: If you get the message "Open of /dev/dsk/c#t#d#s0 failed", you can safely ignore the message (this is a known bug pending a fix). Nothing fancy here. Run 'metadevadm' on the disk, which will update the New DevID. sahil on November 29th, 2011 Thanks for the great information….but i have a small doubt here… I have 2 disks and 3 volumes (suppose v1,v2 & v3) are created on different

You can check to see if this disk defined as a Dump Device or Swap device, and so on. metadevadm -u c0t2d0 Updating Solaris Volume Manager device relocation information for c0t2d0 Old device reloc information: id1,[email protected]_MAG3182L_SUN18G_00526202____ New device reloc information: id1,[email protected]_ST318203LSUN18G_LR7943000000W70708e0We run 'metadb' to recreate the replica that we removed G1 by John ... Moreover, although I can't find the exact reference to confirm, am fairly sure that the es_rcm.pl issue was resolved by 5.0MP1 (which you have) so it still wouldn't apply even if

If there are any replicas on this disk, remove them using metadb -d c#t#d#s# You can verify there are no existing replicas left on the disk by running 'metadb | grep