Oracle VAI View All Topics View All Members View All Companies Toolbox for IT Topics Data Warehouse Groups Ask a New Question Teradata For discussion on Teradata , please visit the it's a modern post apocalyptic magical dystopia with Unicorns and Gryphons Can two integer polynomials touch in an irrational point? what do you mean by consuming process? 0 Kudos Reply CarlosAL Enthusiast Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Direct Link Print Email to a Friend Report Shaan replied Mar 26, 2014 Can you be more specific please? this contact form

Teradata Utility Returned With Error Code 12 | UTY1006 CLI error: 224, MTDP: EM NOHOST(224): name not in HOSTS Sh4nk4r asked Mar 26, 2014 | Replies (8) I am trying to more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Science Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... why not try these out

Teradata Utility Returned With Error Code 12. Aborting On Its Behalf

You may wish to talk to the account representative. –Rob Paller Aug 20 '13 at 20:43 1 You can find more about the Teradata / Hadoop Connector here. Shaan replied Mar 26, 2014 Thanks Every one. Wes Loftis replied Mar 26, 2014 From the messages manual. 224 EM_NOHOST Name not in HOSTS file or names data base.

  • Highest return code encountered = '12'. **** 17:22:09 This job terminated ---------------------------------------------------------------------- /**************************************************************************/ /* */ /* Adapted from Teradata Parallel Transporter User Guide - Job Example 06 */ /* */
  • First screenshot indicates the values that i have given for logon and Second screenshot contains the error after logging in.I am unable to understand the meaning of "Account Id" when loging
  • The Privacy Policy and Terms of Use for this Teradata website changed effective September 8, 2016.
  • You are generating almost 3GB.
  • End : 17:03:21 - TUE AUG 11, 2009 .
  • The Teradata group is no longer active. 5461005 Related Discussions Error while running Fast Export Script Tpump giving wrror WRT_8047 Teradata Demo version installation problem Fastload script logon error Error logging

To start fresh, I droppedall the error log tables in both DB's and deleted all files in the checkpoint directory.Then, when transferring datato the "new" database (different than the user's default), End : 12:28:44 - TUE MAR 24, 2015 . share|improve this answer answered Aug 20 '13 at 14:39 Rob Paller 6,2891422 Thank you all... –DrewRose Aug 22 '13 at 6:38 add a comment| Your Answer draft saved The Teradata Utility Returned With Error Code 12 hth Frank Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving...

Top White Papers and Webcasts Popular Best Practices for a BI and Analytics Strategy Related Forrester Consulting Report: Empowered Customers Drive ... Error Code 12 In Teradata Fastload Well this is not a direct process. Toolbox.com is not affiliated with or endorsed by any company listed at this site. means the retcode is 12? 0 Kudos Reply Teradata Links Teradata.com Teradata Partners Support & Forums Support Portal / TaYS Teradata Aster Community Communities Downloads Documentation Developer Downloads Teradata

Where i am going wrong.FastExport Script.LOGTABLE DB.errors;.LOGON jugal/jbhatt,bhatt;.BEGIN EXPORT; .EXPORT OUTFILE sample111_R_T.txt MODE RECORD FORMAT TEXT; Sel top 10 cast(EmpId as char(15)),cast(DeptId as char(15)) from DB.Employees; .END EXPORT; .LOGOFF;Logs: ======================================================================== The Teradata Utility Returned With Error Code 8 However, due to a backwards compatibility issue (we have to act the way MultiLoad acted), the restart log table handling occurs prior to switching database [email protected]: please provide the exact version MoreWhitePapers Best Answer 1 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... Mode: RECORD .

Error Code 12 In Teradata Fastload

Your use of this Teradata website is governed by the Privacy Policy and the Terms of Use, including your rights to materials on this website, the rights you grant to your Perhaps the actual SQL DATABASE statement? Teradata Utility Returned With Error Code 12. Aborting On Its Behalf Can anyone help me and tell what is the mistake here? Error Code 12 In Teradata Multiload The Privacy Policy and Terms of Use for this Teradata website changed effective September 8, 2016.

TPT_INFRA: TPT02255: Message Buffers Sent/Received = 1, Total Rows Received = 0, Total Rows Sent = 0 Load_Operator: disconnecting sessions ODBC_Operator: disconnecting sessions ODBC_Operator: Total processor time used = '0.03125 Second(s)' weblink teradata share|improve this question edited Aug 20 '13 at 15:06 a_horse_with_no_name 186k24234311 asked Aug 20 '13 at 10:10 DrewRose 3973821 Before you unload loads of data from Teradata to The super user dbc is not having create privileges on the retail database, where i am instructing the utility to create a log table. How to mount a disk image from the command line? Highest Return Code Encountered = '12'

Outlimit: No limit in effect. **** 09:58:09 UTY8715 FastExport is submitting the following request: Select NULL from DB.errors where (LogType = 220) and (Seq = 1) and (FExptSeq = Neeraj_Shrivastava replied Aug 30, 2011 Better is use api method rather fast_export or else make sure that the db user used in dbc file must have create access on database Top End : 07:31:04 - WED MAR 26, 2014 . http://bashprofile.net/error-code/failed-validation-and-returned-error-code-0xc020801c.html All rights reserved.

Why is the spacesuit design so strange in Sunshine? Then I changed the target Teradata DB to a different DB, and now I'm getting a return code 12 during INSERT operator. Explanation: The DBC/1012 name was not found in the workstation's hosts file or names data base.

So you would need to figure out why the consuming process aborted / closed the pipe. 0 Kudos Reply nimish_123 Enthusiast Options Mark as New Bookmark Subscribe Subscribe to RSS Feed

Where can I find more information about this error? The Privacy Policy and Terms of Use for this Teradata website changed effective September 8, 2016. When transferring data to the user's default database, all error tables are created in the default database, and there is no error. ALL RIGHTS RESERVED. = = = ========================================================================0003 .LOGTABLE P0_OR_SBL.FE_FE_V_DM_CM_DIM_AGREEMENTS;0004 .DATEFORM ANSIDATE;**** 10:38:02 UTY1200 DATEFORM has been set to ANSIDATE.0005 .LOGON prd/P0_SBL_LOADER,;**** 10:38:04 UTY8400 Teradata Database Release: 14.00.07.07**** 10:38:04 UTY8400 Teradata Database

Highest return code encountered = '12'. 0 Kudos Reply All forum topics Previous Topic Next Topic 5 REPLIES nimish_123 Enthusiast Options Mark as New Bookmark Subscribe Subscribe to RSS Feed Get Solve problems - It's Free Create your account in seconds E-mail address is taken If this is your account,sign in here Email address Username Between 5 and 30 characters. Start : 10:38:02 - TUE MAR 24, 2015 . his comment is here Community Teradata Community Browse Register · Sign In · Help Error Accessing Fast Export Utility Tools All communityThis categoryThis boardKnowledge baseUsers turn

Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes | No Saving... UTY8732 0.02 blocks processed per minute (5-minute sample). I am working in windows platform. In nomenclature, does double or triple bond have higher priority?

How many answers does this question have? Loading Table Using Update Table Component With Mload Utility Error while loading into Teradata table using thru PT-UPDATE mode Extract from Teradata fails when using 'FastExport' Error while loading data from Thanks a lot people in advance :) Have a great day ! 0 Kudos Reply All forum topics Previous Topic Next Topic 2 REPLIES ulrich Junior Supporter Options Mark as New However, for historical reasons, we create the log table prior to issuing the DATABASE request.

And I am not sure where to find my tpid incase I need to mention it, but the syntax says its optional and a default value ll be added in case The table GP_ORA_STAGE was indeedcreated in Teradata, but I get the message "is being loaded" when I try to SELECT from the table. DEFINE OPERATOR Load_Operator TYPE LOAD SCHEMA * ATTRIBUTES ( VARCHAR PrivateLogName = 'load_log', VARCHAR TdpId = 'ghstdanx', VARCHAR UserName = @UsrID, VARCHAR UserPassword = @Pwd, VARCHAR WorkingDatabase = FEAS', VARCHAR TargetTable C:\Program Files\Teradata\Client\13.10\Teradata Parallel Transporter\logs>tlogvi ew -j XG_MEDMINING_OR_MANUFACTURER-615 TPT_INFRA: TPT04101: Warning: TMSM failed to initialize Teradata Parallel Transporter Coordinator Version 13.10.00.04 Teradata Parallel Transporter Executor Version 13.10.00.04 Teradata Parallel Transporter SQL DDL

It needs to be decreased to something lower than the max allowed for your TD database. I want to learn which parameters in TPT script will affect the "Data Block Size" and how to tune it in the positive way.Task(SELECT_2[0008]): checkpoint completed, status = Success

UTY8732 0.02 blocks processed per minute (running average).**** 12:28:38 UTY4014 Access module error '34' received during 'write' operation: 'pmunxWBuf: fwrite byte count error (System error message detected: 32)'**** 12:28:38 UTY8721 Error But in reality it isn't.